EPIRB: float-free release and access to the container

When selecting NSR NEB-2000 the container location must be considered alongside the beacon itself. It must meet two distinct needs: the intended float-free release and the ability to take the equipment manually to a survival craft. A mounting area of suitable size and the presence of a hydrostatic release unit do not, by themselves, describe these conditions on a particular vessel.

Request a quote

Conceptual closed EPIRB container on an open bridge area with clear access; an editorial illustration of its surroundings.
Conceptual location for discussing access and surrounding structures. The drawing does not confirm float-free release of a particular package or approval of its location.

Why the NEB-2000 is considered here

NSR describes the NEB-2000 as a satellite AIS EPIRB with automatic hydrostatic release and manual operation. Selection requires checking the exact package version and its associated documents.

This article considers section 4.9 of Part VII, Radio Equipment, of the RKO Rules for the Classification and Construction of Ships, introduced on 3 April 2026 by Order No. 29-p, taking subsequent amendments into account. Clauses 1.1.1–1.1.3 establish the scope of the Part: inland and mixed-navigation vessels and radio equipment subject to RKO survey for vessels of its class. Under clause 1.1.2, unless otherwise specified, vessels and products in service are subject to the rules under which they were built or manufactured. Additional Administration instructions are considered under clause 1.1.5. The required equipment and applicable edition are established using the vessel documents.

Consider the entire clear space

Subclause 4.9.1.1 requires a location with the greatest probability of the EPIRB floating free. Guardrails, superstructure components and other structures must not obstruct it as the vessel sinks.

An enquiry benefits from an overall view of the location and information about the container's surroundings. A close-up of the beacon alone does not show an overhanging structure, railing or other obstruction. If an old location is to be retained, assess its current configuration: new components may have appeared nearby after alterations.

The hydrostatic release unit is a feature of the package. Its presence alone does not establish that the vessel presents no obstructions. Check the exact container, mounting and release-device versions against the selected beacon's documentation; a similarly shaped holder is not automatically suitable.

The container must be accessible

Under subclause 4.9.1.2, one person must be able to release the EPIRB manually and carry it to a survival craft. Installation on a mast or in another location accessible only by a vertical ladder is not permitted.

The initial information therefore needs to describe access to the equipment as well as installation height. Explain where it is approached from and what is known about the route for carrying it. Do not remove an operational beacon or test its release device yourself merely to prepare a commercial quotation.

Clause 4.9.2 addresses a separate condition: the EPIRB is used as one of the two mandatory independent ship-to-shore alerting means available from the conning position. Additional location requirements apply in this case. Clause 4.9.5 separately considers passenger vessels where an installed satellite EPIRB serves as the second mandatory alerting means and is not remotely activated. These conditions cannot be applied to every EPIRB order; its role within the equipment arrangement must be stated before choosing a location.

The buoyant lanyard is also part of the package

Clause 4.9.3 specifies a manufacturer's buoyant lanyard suitable for securing the beacon to a liferaft or similar craft. Its arrangement must prevent snagging on ship structures. Selection must therefore retain the connection between the particular beacon, its intended accessories and its location. An arbitrary similar lanyard must not be declared an equivalent replacement without documentation.

What to attach to the request

Background informationThe question it addresses
Vessel, class and current equipment documentsApplicable edition and the EPIRB's role
Overall container location and surrounding structuresPotential obstructions to floating free
Access to the location and route to a survival craftAccess and carrying by one person
Identifiers of the beacon, container and release deviceComponents to retain and replace
Accessory package and known issuesWhat must be confirmed in the quotation

For NEB-2000 specify the exact versions and the boundaries of work at the installation location in the quotation. A product name alone does not establish installation of the container or readiness of the entire emergency system. Condition, documents, contents, availability, price and lead time must be confirmed for the particular supply.