BC-197 #13: AD-121, BP-265 and the protection timer
Equipment: functions and package contents
When ordering the six-position BC-197, retain the version number. The Inlight group catalogue specifies #13, but its description lists different radios depending on the installed inserts. The Icom manufacturer table narrows the question to a particular configuration: Ver13, EUR-01, AD-121 charging adapters and the BP-265 battery.
Icom BC-197 #13 — group catalogue product page

The same name, different adapters
The manufacturer table distinguishes several BC-197 configurations. Examples of European versions show why the main product name alone is insufficient:
| Version | Charging adapter | Battery according to the Icom table |
|---|---|---|
| Ver03 | AD-120 | BP-264 |
| Ver13 | AD-121 | BP-265 |
| Ver33 | AD-129 | BP-245H for the IC-M73 |
All three entries specify the European-version BC-157S AC adapter. A common power supply does not make the charging inserts identical. A quotation for a BC-197 with a European plug therefore does not yet establish the required compatibility with the department's batteries.
The manufacturer description specifies simultaneous charging of up to six batteries. This is the capacity of the relevant configuration, rather than permission to insert any six Icom batteries. List their full identifiers in the specification, with the radio models as additional information for checking the complete configuration.
Checking an existing installation
If a BC-197 is already installed at the site, provide the markings on the main unit, charging adapters and batteries in use. A radio name without battery details leaves uncertainty: the service may have changed its batteries during operation.
When ordering #13, ask for the actual AD-121 adapters, compatible BP-265 batteries and power supply to be recorded in a single hardware schedule. This confirms the selected supply configuration. It is not a recommendation to replace inserts yourself or mix versions; the possibility of reconfiguration must be considered separately using the applicable documentation.
Protection timer and charging time
The Icom page includes an Overcharge protect timer entry: 2.5 hours for Ni-MH and 4.25 hours for Li-ion. Its name refers to the protection timer. These figures must not be presented as a promise that any battery will charge fully in exactly that time.
Equipment issue scheduling needs a separately agreed outcome: which batteries are returned, their condition, when they must be ready and how this is confirmed. If the time needed to prepare a batch must be checked, define the conditions and form of the record. Retain the timer specification with its original meaning.
What should accompany the charger
For a quotation, provide the battery quantity and identifiers, number of positions to be used simultaneously, and existing equipment. Request a single schedule listing the BC-197 version, installed charging adapters, mains power supply and accessories. Preparation and verification of the selected configuration are agreed as a separate scope.
Icom marks the manufacturer BC-197 page as discontinued; the specific #13 product page remains a basis for requesting a quotation. Confirm condition, contents, documents, availability, price and lead time before ordering. This links #13 to a verifiable configuration rather than a general list of radios in the family description.
Sources: Icom Inc., BC-197 descriptions/specifications/version list.